Upload a CT series and Sona outlines the organs, slice by slice and in 3D, with their volumes. The scan never leaves Malaysia. On a chest CT, it also suggests possible lung nodules for the radiologist to review. For the patient, a 3D body on iPhone explains what the report says.
51 / 107Lung · W 1500 L -600
Drag the slice bar to move through the scan, or pick an organ to find it.
Organs Volume
Volumes are from the outlines, computed in AWS Asia Pacific (Malaysia).
Airway route
Research preview · not for procedure planning
- Along the airways
- 213 mm
- From the trachea
- 5 forks
Ends 7 mm before the nodule, where the airways found end.
The public LIDC-IDRI-0001 chest CT (TCIA, CC BY 3.0) with the outlines and route Sona computed for it, as Sona Pro shows them. Not any patient of ours.
New · Research preview
AI lung-nodule suggestions for the radiologist
On a chest CT, a nodule detector runs on a GPU after the organ outlines and suggests possible lung nodules. Each one waits for a radiologist or clinician to look, accept or reject it. AI suggestion for radiologist review, not a diagnosis.
Clinician, Sona Pro on the web
Recorded on staging: Demo Clinic, synthetic patient data, on the public LIDC-IDRI-0001 chest CT.
The AI impression card
- Finding
- Lung nodule, about 25 mm, left lower lobe (slices 88–97)
- Finding (AI draft, sign to keep)
- Nodule, about 25 mm, left lower lobe (slices 88–97). AI-suggested, confirmed by Dr Nur Hazwani binti Mokhtar.
- Confidence
- High detector score (1.00)Sensitivity 86% at 4 false positives per scan on 89 public LUNA16 scans it never trained on
- Suggested next step
- For a nodule over 8 mm: consider CT at 3 months, PET/CT, or tissue samplingSuggestion, clinician decides. Fleischner Society 2017, Radiology 2017;284(1):228–243
Try it: accept the suggestion, then sign the finding. In Sona Pro, signing takes the clinician's passkey or Face ID.
-
Show it on the slice
Show moves the CT to the suggestion's middle slice and draws its box, dashed, in the AI lavender no organ outline wears. In 3D it is a sphere among the organs.

The suggestion on its slice and in 3D. Public CT, Demo Clinic. -
Accept or reject it
Nothing is accepted by the software. A clinician accepts or rejects each suggestion, and every decision goes in the audit log with the model that made it.

The AI impression, accepted. Demo Clinic, synthetic data. -
The doctor signs the finding
Accepting drafts one sentence: size, place and slices, nothing more. Never density, type or malignancy. The doctor edits it and signs it; it is never signed for them.

The draft, waiting for the doctor's signature. -
Pick the follow-up
The card shows the Fleischner Society 2017 row for the nodule's size, low risk and high risk, word for word. The detector knows neither the density nor the patient's risk, so the clinician picks.

Low risk picked, from the guideline's own table. -
Refer to respiratory, after approval
Refer to respiratory drafts the referral letter from the signed record, with the finding and its slices. It waits in Approvals for a clinician, as every referral letter does, and is never sent on its own.

The referral letter waiting for approval. Demo Clinic, synthetic data.
Measured on public research CTs from the US, not on Malaysian patients. With 112 nodules the range is wide (77% to 93%), and small nodules under 6 mm are found least. The scan and the suggestions stay in AWS Asia Pacific (Malaysia).
How it works
From a DICOM zip to a body she can turn
Outlines are for clinicians, on an Explainer in Sona Pro. What the patient gets is a separate, illustrative 3D body, released by a clinician.
-
Upload the CT series
One zip of DICOM files, up to 500 MB, on the patient's Explainer. Patient details are stripped from every file before anything reads it, and the original zip is deleted.
- CT series, one zipDICOM files, up to 500 MB
- De-identified firstNames and IDs out of every file header; study IDs replaced
- Original deletedOnly the de-identified series is kept
- Outlined in MalaysiaOn a server in AWS Asia Pacific (Malaysia), reaching only its own storage
What happens to the scan, in order. -
Organs outlined, slice by slice
TotalSegmentator, an open model, outlines the organs the report's findings name. On the demo abdominal CT it took 45 seconds billed, about RM 0.03 per CT.

Sona Pro on the web, split view. Public sample CT. -
Turn it in 3D, with volumes
The outlines become a 3D model you can turn, and each organ gets its volume in mL. For a lung nodule, an airway route from the trachea is a research preview, about RM 0.30 per route. Record search finds a study by its report and opens it at the cited slice.

The 3D view, expanded, with the airway route in orange. -
Explain it on her iPhone
When a clinician releases the Explainer, she sees an 18-part body in Sona Care, with the part her report names marked. She turns it all the way round and pinches to zoom. It is labelled "Illustrative, not your scan".

Sona Care on iPhone, a released Explainer for a demo patient.
What clinicians and patients see
Outlines for you, a body for her
The clinician gets the slices, the 3D model and the volumes. The patient never sees an outline; she sees an illustration of the part her report talks about.
Clinician, Sona Pro on the web
Every slice, mesh and volume carries "AI organ outline, not a diagnosis".
Patient, Sona Care on iPhone
She can turn it, tip it and pinch to zoom. It follows Reduce Motion, and VoiceOver reads it as "Body picture".
Guardrails
An outline, never a reading
- The scan stays in Malaysia
Outlines run in Sona's own cloud in AWS Asia Pacific (Malaysia), with network access to its own storage only. A hosted outlining service was turned down because the scan would leave Malaysia.
CT outlines, ADR 0031 - Not a diagnosis
Every outline, mesh and volume is labelled "AI organ outline, not a diagnosis". The organ outline does not look for lesions; the nodule in the hero is the radiologists' own. Nodule suggestions come from a separate detector, say "AI suggestion for radiologist review, not a diagnosis" and wait for a clinician to accept or reject them. They are a research preview, not registered with Malaysia's Medical Device Authority.
Explainer, CT viewer - Clinicians only
Only clinicians can upload or view a CT. A clinic admin without a clinician role is refused, and outlines never reach a patient. Nor do nodule suggestions, signed findings or follow-ups.
Permission, imaging.ct - De-identified before it is read
Patient details are taken out of every DICOM file and study IDs are replaced. The original zip is deleted.
CT upload, de-identification - The route is a research preview
The airway route says "Research preview · not for procedure planning", and it never claims to reach further than the airways the model found.
CT viewer, airway route - A clinician releases what she sees
The patient's 3D Explainer appears only after a clinician releases it, and it says "Illustrative, not your scan".
Explainers, release